top of page
AVEVA™ Communication Drivers
used with AVEVA InTouch HMI or AVEVA System Platform
AVEVA has decoupled their Drivers from the SCADA itself. As such it is easier to maintain and update these drivers, both for AVEVA and for anyone that is using the drivers.
Standard Drivers
Driver Name | Vendor | Description |
---|---|---|
ABCIP | Allen-Bradley | Supports the logix platform from Allen-Bradley including ControlLogix, GaurdLogix, CompactLogix, FlexLogix, SoftLogix, and MicroLigix. Supports legacy SLC 500 Ethernet controllers. Supports bridge connectivity to legacy PLC5 and SCL 500 via DH+ and ControlNet networks. Supports AutoBuild for Logix controllers. |
ABTCP | Allen-Bradley | Support for Allen-Bradley legacy platforms including PLC-5 and SLC5-500 controllers. |
BACLITE | Standards | Supports the BACNet/IP Communication protocol |
CODESYS | Standards | Supports connectivity to Codesys-based controllers of versions 20x and 3.x. The following have been tested: Bosch Rexroth-L40 and L65, SP WIN V3.5.1 Control, SP PLCWinNT V2.4.4.0, EATON XC-CPU202, SE 241/M251, WAGO CPU 750-841 |
GATEWAY | Standards | Allows connectivity to SuiteLink, OPC DA, OPC UA, InTouch, and Application Data sources. Then exposes data via SuiteLink and OPC DA to software clients. Reverse connect also possible as of 2023 R2 versions. |
GESRTP | General Electric | Supports Series 90-30, Series 90-70, Versamax, Versamax Micro, Versamax Nano, and PACSystems (RX3i, RX7i) controller families. |
MBTCP | Modicon | Supports generic Modbus TCP, Modicon family of controllers including TSX Quantum, TSX Momentum, TSX Premium, and also supports Modbus Bridge. |
MELSEC | Mitsubishi | Supports the controller families MELSEC-Q, MELSEC-QnA, and MELSEC-L. |
MQTT | Standards | Not a broker. Supports traditional JSON-based simple and nested MQTT payloads based on MQTT 3.1.1 specification. Supports for Eclipse foundation Sparkplug MQTT Industrial Specification 1.0 B (Sparkplug-B). |
OMRONFINS | Omron | Supports for Omron Ethernet-based controllers supporting the FINS network protocol including CJ1, CJ2, CS1, CP1, CV, CVM1 series. |
SIDIRECT | Siemens | Supports Siemens S7-1200, S7-1500 platform in both legacy and symbolic modes, over Ethernet. Supports Siemens S7-300, S7-400 controllers. Supports AutoBuild for S7-1200 and S7-1500 controllers. Does not support S7200. |
SIM | Internal | Supports simulation of Discrete, Integer, Real (Float/Double Float), and String data types through OPC or SuiteLink. It has advanced data simulation capabilities for setpoint, noise, and process value tracking. |
SNMP | Standards | Supports SNMP versions V1, V2C, V3. |
SOMAC | Schneider-Electric | Supports the Logic Controllers Modicon M241 PLC and Modicon M251 PLC. Also, supports the Motion Controllers PacDrive 3 LMC Eco/ Pro/Pro2. |
TI500 | Texas Instruments | Supports the Control Technology Inc. – CTI2500 (replacing the TI500’s series). Supports the controllers – TI545 / 565 / 575. Supports Serial and Ethernet connectivity |
TWINCAT | Beckoff | Leverages the TwinCAT ADS communication library for communication and supports any TCP/IP Ethernet Beckoff device compatible with the ADS Library version you install: CX1010, CX1020, CX1030, CX2000, CX5000, CX5100, CX8000, CX9000. |
WEBSVC | Standards | Supports communications with client web services over an HTTP/S network using: Simple Object Access Protocol (SOAP) (XML payload format only), Representational State Transfer (REST) (XML, JSON format supported). Secured connectivity limited to REST-based web servers. |
Telemetry Server
Telemetry Server is a separate offering designed to complement the supervisory communication portfolio, by adding specific advanced drivers.
Tight integration with AVEVA System Platform.
IEC 61850
Supports IEC 61850 client functionality.
MODBUS RTU
Supports Modbus RTU Serial, ASCII Serial, as well as Modbus RTU over TCP and over UDP including ASCII flavors.
IEC 60870
Supports IEC 60870-5-101 for serial communications as well as IEC 60870-5-104 for TCP.
DNP3
Supports DNP3 client functioanlity.
bottom of page